The Amphion Edge device is robust and able to handle various types of data collection. This article lists each step required to successfully set up and start collecting data from your devices.
ei3‘s data collection services are optimized for an ever-growing list of specific control systems. While the current data collection services available are only for certain automation control system protocols, ei3 can set up collection using any other types – even those which are currently not supported by the Amphion, through its ei3 private cloud services. Contact us for assistance.
When you set up a machine in ei3 for Amphion data collection using one or more of the supported protocols, you must choose from these predefined device types in ei3 for all of the devices from which you will be collecting data. If you have any devices that are not supported by the Amphion, then you can use ei3‘s cloud services for all of your devices simultaneously.
In order to properly set up your data points, here are links to more articles to guide you. If you have any questions, please contact us for additional resources.
Prerequisites to starting Data Collection
What is required before starting data collection on a machine?
Data Point Setup
- Adding, Editing, and Removing Data points via XML
- Adding, Editing, and Removing Data Points using Excel Files
- Adding, Editing, and Removing Data Points Manually
Amphion Edge Device Collection
- OPC-UA Data Collection
- Rockwell & eWOD Data Collection
- XML JSON Data Collection
- Emerald PLC Data Collection
- CAMAC 486/XTL/VEL Data Collection
Starting, Stopping, and Editing Data Collection
Supported Device Types
The device types that enable Amphion collection of Rockwell or eWOD data are:
- Rockwell – PLC (MicroLogix,slc505,plc5e) (Amphion)
- Rockwell – PLC (ControlLogix,CompactLogix,FlexLogix) (Amphion)
- Bobst – eWOD (Amphion)
The device types that enable Amphion collection of JSON or XML data are:
- Generic – JSON (Amphion)
- Generic – XML (Amphion)
The device type that enables Amphion collection of OPC-UA data is:
- Generic – OPCUA (Amphion)
The device type that enables Amphion collection of data from devices supporting the S7 protocol from Siemens is:
- Siemens – PLC S7 TCP ISO Protocol (Amphion)
The device types that enable Amphion collection of data from B&R devices are:
- B&R – Binary (Amphion)
- B&R – Milacron (Amphion)
The device types that enable Amphion collection of data from Shibaura’s devices are:
- Shibaura – Injection Molding V50/V70 (Amphion)
- Shibaura – TOSCAST 888/555 (Amphion)
The device type that enables Amphion collection of data from the Emerald Automation Controller is:
The device type that enables Amphion collection of data from Milacron’s CAMAC 486/XTL/VEL controls is:
Other Useful Links
© 2024 ei3 Corporation. Content of this web page is proprietary to ei3 Corporation.